sempermed® syntegra IR

The award winning syntegra IR is a polyisoprene surgical glove with latex properties is not only latex-free but powder-free. Its specially developed synthetic inner coating quick-don™ allows for quick donning.

Find distribution partner

Description

The prophylaxis for latex allergy:
The innovation in the operating room as the synthetic polyisoprene (IR) excels with the same physical properties as natural latex - maximum elasticity and tear resistance, with low tension.

Benefits

  • FREE FROM NATURAL RUBBER LATEX
    Synthetic polyisoprene benefits surgeons, surgical staff and patients, free from allergenic proteins, powder-free. 
     
  • PERFECT GRIP
    Through mirco-rough surface, even in a moist environment.
     
  • TACTILE SENSE
    Like natural rubber latex gloves.

Specifications

Type

Sterile surgical glove for single use, with synthetic inner coating

Material

Synthetic polyisoprene, free from natural rubber latex

Internal finish

Powder-free polymer coated

Glove surface

Smooth

Colour

Cream

Glove Shape

Fully anatomical with curved fingers and rolled rim

Size

Overall length as per EN 455-2
5 ½, 6 and 6 ½            min. 270 mm
7, 7 ½ and 8                min. 280 mm
8 ½ and 9                    min. 285 mm

Wall thickness

Measured in double layer in the palm area
0.43 +/- 0.05 mm

Barrier performance

Tightness as per EN 455-1
AQL 0.65 

Force at break

as per EN 455-2
median ≥ 9 Newton 

Durability

in original packaging if stored as per ISO 2230
3 years

Sterilisation

Irradiation

Labeling & CONFORMITY TO STANDARDS

EN 1041, EN 455, EN 420, EN 421, EN 374, ISO 15223

Packaging

Left and right glove with turned up cuff in inner pouch, ozone-tight, sealed in medical peel pack.
In dispenser carton with sterilisation indicator: 50 pairs
In transport carton with sterilisation indicator: 300 pairs

INTENDED PURPOSE

  • Medical device class IIa as set out in MD Directive 93/42/EEC
  • Single use protective glove – PPE category III (protection against chemical substances for limited time*) as set out in PPE Regulation (EU) 2016/425 

 

*Please note that all Sempermed products must be used in accordance with the Sempermed chemical resistance and the respective declaration of conformity.

Failure to observe this information, in particular with regard to chemical resistance, frequency of use and tolerability of the gloves, can result in personal injury and/or material damage. Sempermed is not liable for incorrect use of the gloves nor will Sempermed be liable for improper storage and handling. In case of indications of damage or unusual signs of wear and tear to the gloves, the gloves should not be used. In case of any doubt, expert advice should be sought before use. This information and classification is up to date as of the date of the last update to this page. Technical details are average values from production and may vary in individual cases. This disclaimer is subject to mistakes, printing errors and amendments.

 