To the content

sempermed® supreme green

DOUBLE PROTECTION THAT YOU CAN TRUST: The latex surgical underglove in green colour for clear detection of perforations when double gloving. It is powder-free with quick-don™ synthetic inner coating.

Find distribution partner

Description

Double protection that you can trust:
The green colour facilitates the detection of a glove perforation during surgery. In combination with sempermed® supreme or sempermed® supreme plus, sempermed® supreme green constitute the optimum glove solution with regards to safety and comfort.

Our surgical glove artwork has changed recently. Please find all information on the changes here. ​​​​​​​

Benefits

  • THE IDEAL INNER GLOVE
    sempermed® supreme green is the ideal inner glove for double gloving, an increasingly common practice aiming to optimise protection against infections. The surgeon wears two pairs of gloves in order to be able to quickly recognise outer glove perforations, which otherwise often go unnoticed. If liquid gets in between the gloves, it forms a clearly visible stain so that the outer glove can be changed immediately. The green colour of the inner glove reinforces the staining caused by the liquid.
     
  • THINNER WALL THICKNESS - MORE TACTILE SENSE
    sempermed® supreme green has been adapted according to sempermed® supreme and can be donned more easily because of the smooth surface structure. The wall thickness has been reduced significantly to ensure an even higher sensitivity with consistent security.
     
  • EASY DONNING THANKS TO QUICK DON
    The synthetic inner coating of the sempermed® supreme green gloves makes them easy to don and facilitates changing gloves during surgery.

Specifications

Type

Sterile surgical glove for single use, with synthetic inner coating

Material

Natural Rubber (NR) 

Internal finish

Powder-free polymer coated

Glove surface

Micro-rough

Colour

Green

Glove Shape

Fully anatomical with curved fingers and rolled rim

Size

Overall length as per EN 455-2
5 ½, 6 and 6 ½            min. 270 mm
7, 7 ½ and 8                min. 280 mm
8 ½ and 9                    min. 285 mm

Wall thickness

Measured in single layer in the palm area
0.19 +/- 0.02 mm

Barrier performance

Tightness as per EN 455-1
AQL 0.65 

Force at break

as per EN 455-2
median ≥ 12 Newton 

Shelf Life

in original packaging if stored according to product specification
3 years

Sterilisation

Irradiation

Labeling & CONFORMITY TO STANDARDS

EN 1041, EN 455, EN 421, EN 374, EN 16523, EN ISO 21420, ISO 15223

Packaging

Left and right glove with turned up cuff in inner pouch, ozone-tight, sealed in medical peel pack.
In dispenser carton with sterilisation indicator: 50 pairs
In transport carton with sterilisation indicator: 300 pairs

INTENDED PURPOSE

  • Medical device class IIa as set out in MD Directive 93/42/EEC
  • Single use protective glove – PPE category III (protection against chemical substances for limited time*) as set out in PPE Regulation (EU) 2016/42 

 

*Please note that all Sempermed products must be used in accordance with the Sempermed chemical resistance and the respective declaration of conformity.

Failure to observe this information, in particular with regard to chemical resistance, frequency of use and tolerability of the gloves, can result in personal injury and/or material damage. Sempermed is not liable for incorrect use of the gloves nor will Sempermed be liable for improper storage and handling. In case of indications of damage or unusual signs of wear and tear to the gloves, the gloves should not be used. In case of any doubt, expert advice should be sought before use. This information and classification is up to date as of the date of the last update to this page. Technical details are average values from production and may vary in individual cases. This disclaimer is subject to mistakes, printing errors and amendments.

This product contains accelerators of Dithiocarbamate types. These products should not be used if hypersensitivity of these substances exists. For further information, a list of substances contained in the glove is available upon request.

CAUTION: Natural latex can cause allergic reactions, including anaphylactic shock. Sempermed bears no liability for allergic reactions.

 

To the main navigation
Back to Surgical Gloves