sempermed® safe

FEEL YOUR SAFETY: A powder-free, nitrile disposable protective glove with enhanced protection thanks to significantly higher typical forces at break, tested according to EN 455-2.

Find distribution partner

Description

The tried and tested safety of a nitrile examination glove – combined with wearing properties similar to latex – makes sempermed® safe for an optimum glove solution without natural rubber latex proteins.

Benefits

  • Glove material is resistant to blood and other body fluids, and protects against bacteria, fungi and viruses including SARS-CoV-2, Hepatitis B & C and HIV.
  • Enhanced protection thanks to a significantly higher typical force at break, which has been tested according to EN 455-2.
  • The soft material increases wearing comfort and makes it comfortable and safe to work with, even for longer periods.

Specifications

Type

non-sterile, powder-free examination glove for single use

Material

Nitrile Butadiene Rubber (NBR)

Internal finish

Powder-free

Glove surface

Finger textured

Colour

Ocean blue

Glove Shape

Flat with rolled rim, ambidextrous

Size

Overall length as per EN 455-2
S, M, L, XL median 240 mm

Wall thickness

measured in single-layer in the palm area
min. 0.08 mm
typical 0.09 mm

Barrier performance

Tightness as per EN 455-1
AQL 1.0 

Force at break

as per EN 455-2
median ≥ 6 Newton / typical ≥ 9 Newton

Shelf life

in original packaging if stored according to product specification
5 years

Labeling & CONFORMITY TO STANDARDS

EN ISO 21420, EN ISO 374-1, -2, -4, -5, EN 16523-1, EN 421, EN 455, ASTM F1671/F1671, ASTM D6319

Packaging

100 pcs / dispenser S, M, L
90 pcs / dispenser XL

INTENDED PURPOSE

  • Single-use medical device class I as set out in MD Regulation (EU) 2017/745 
  • Single-use protective glove – PPE category III (protection against chemical substances for limited time)* as set out in PPE Regulation (EU) 2016/425
  • Suitable for food contact as set out in Regulation (EC) 1935/2004 on Food Contact Materials 

 

*Please note that all Sempermed products must be used in accordance with the Sempermed chemical resistance and the respective declaration of conformity.

Failure to observe this information, in particular with regard to chemical resistance, frequency of use and tolerability of the gloves, can result in personal injury and/or material damage. Sempermed is not liable for incorrect use of the gloves nor will Sempermed be liable for improper storage and handling. In case of indications of damage or unusual signs of wear and tear to the gloves, the gloves should not be used. In case of any doubt, expert advice should be sought before use. This information and classification is up to date as of the date of the last update to this page. Technical details are average values from production and may vary in individual cases. This disclaimer is subject to mistakes, printing errors and amendments.

This product contains accelerators of Dithiocarbamate types and Zinc-mercaptobenzothiazol. These products should not be used if hypersensitivity of these substances exists. For further information, a list of substances contained in the glove is available upon request.

 